  Code: M88A - Hand dryer Junior sensor operated white ABS  

Data Sheet (72 KB)
CAD Drawing (64 KB)
High Resolution Picture (41 KB)
Installation Manual
Certificates
Spare Parts
   
Print

 
  * General Description  
 
• Warm air hand dryer.
• Sensor operated.
• Suitable for medium traffic facilities.
• Compact, maintenance-free.
• Highest durability in its class.
• It normally goes along with a soap dispenser.
 
  * Components and Materials  
 
• White ABS thermoplastic one-piece cover, 3 mm thick. Cover fixed to the base by means of 4 Phillips head screws.
• Thermoplastic PP+ talcum base, with 4 Ø 8 mm holes for wall mounting.
• Induction motor, 2.800 rpm, maintenance-free and high durability, incorporates a self-resetable thermal cut-off at 130 ºC.
• PP UL94-VO with single inlet fan wheel.
• Waved wire NiCr heating element that incorporates a self-resetable thermal cut-off at 80 ºC.
• Two distances (15/25 cm) IR electronic detection sensor.
• Stainless steel air outlet grill.
 
  * Technical Specifications  
 
Voltage 220-240   V
  Frequency 50/60   Hz
Electrical isolation Class II  
  Dimensions 300x 252x 133   mm
Weight 3   Kg
  Effective airflow 160 m³/h / 2.670 l/min  
Nominal airflow 200 m³/h 3300 l/min  
  Air velocity 60   Km/h
Total power 1.650   W
  Motor power 140   W
Heating element power 1.510   W
  Consumption 7   A
RPM 2.800  
  Air temperature(10 cm distance / 21 ºC) 51   ºC
Noise level (at 2 m) 60   dB
  Protection level IP23  
 
     
  * Operation  
 
Place the hands under the air outlet grill. The dryer will start automatically, and go on with no interruption as long as the hands are kept in the detection range of the sensor. The appliance will stop 2 seconds after the hands are removed from the airflow.
 
  * Specification  
  Surface mounted hand dryer shall be manufactured with one-piece 3 mm thick high-quality thermoplastic ABS cover fixed to the base by means of 4 Phillips head screws. The back base shall be thermoplastic PP + talcum and with 4 holes Ø 8 mm for wall mounting. The dryer shall be activated through an infrared electronic sensor and shall automatically turn off two second after hands are removed. The maintenance-free induction motor shall be 140 W, 2.800 rpm and incorporate a self-resetable thermal cut-off which will disconnect at 130 ºC. The waved wire NiCr heating element should incorporate a self-resetable thermal cut-off which will disconnect at 80ºC. The thermoplastic PP fan wheel should have a single inlet. Dryer shall deliver 160 m3/h of air at 51 ºC and 60 Km/h velocity during user controlled drying cycle. The dryer shall have a total power of 1.650 Watts with a consumption of 7A. Noise level should be 60 dB at 2m distance. Protection level against water splashes should be rating IP23. Overall dimensions shall be 300 x 252 x 133 mm. Unit should be VDE approved and CE marked and comply with electrical safety directives 73/23/CEE & 93/68/CEE and electro-magnetic compatibility directives 89/336/CEE & 92/31/CEE.

Surface mounted hand dryer shall be model M88A sensor operated ABS cover, manufactured by Mediclinics S.A., C/ Industria 54, E-08025 Barcelona, Spain.
 
* Installation  
 
 
* Serial Installation  
 
 
     
  Nº dryers to be fitted:  
  In toilet areas with a normal frequency of use and only one wash-basin: 1 dryer.
In toilet areas with a normal frequency of use and more than one wash-basin: 1 dryer for each 2 wash-basins.
1 row of 4 wash basins: 2 dryers; 1 row of 6 wash basins: 3 dryers; 1 row of 8 wash basins: 4 dryers.
In toilet areas with high traffic and more than one wash-basin: 2 dryers for each 3 wash-basins.
1 row of 4 wash basins: 3 dryers; 1 row of 6 wash basins: 4 dryers; 1 row of 8 wash basins: 5 dryers.
 
  Ideal Location:  
  Between the wash-basin and exit. It is not recommended to install dryer between wash-basins, next to urinals, lavatories and showers. If installing automatic dryers over marble surface or ledge, the minimum distance from the dryer to the ledge must be 400 mm. It is recommended that hand dryers be distributed throughout the washroom area to avoid overcrowding.  
  Recommended heights
Distance from the floor
 
   
  Mediclinics, S.A., reserves the right to make changes and/or modifications to the products and their specifications without prior notice.  
     